OPTICAL SYSTEM DEVICE
Paper Size Sensors
Model No.
Features
Operating
temperature
Topr
(°C)
GP2D03J0000F
GP2D032J0000F*
4
GP2D06J0000F
GP2D061J000F*
2
GP2D062J000F*
2
GP2Y2E101K0F
8-bit serial output using optical distance
measuring method (2-beam)
8-bit serial output using optical distance
measuring method (1-beam)
Thin type (T: 11 mm)
8-bit serial output using optical distance
measuring method (1-beam)
Thin type (T: 11.5 mm)
using optical distance measuring method
(1-beam)
Digital output (1-bit)
8-bit serial output using optical distance
measuring method (3-beam)
Thin type (T: 11 mm)
8-bit serial output using optical distance
measuring method (3-beam)
Thin type (T: 11.5 mm)
Analog output using optical distance
measuring method (1-beam)
Thin type (T: 11.5 mm)
Analog output using optical distance
measuring method (2-beam)
0 to +60
0 to +60
Supply
voltage
Vcc
(V)
5 ±0.5
5 ±0.5
Paper
detection
height
H
(mm)
TYP. 60
TYP. 60
LED beam
pitch
Lp
(mm)
TYP. 21
Approved value of
paper
position sliding
∆x
(mm)
MAX. ±6
MAX. ±6
Paper
detection
density
OD
0.7 or less*
1
0.7 or less*
1
(Ta = 25°C)
Dissipation
current
Icc
(mA)
TYP. 30
TYP. 33
0 to +60
5 ±0.5
TYP. 85
MAX. ±6
0.7 or less*
1
GP2Y2D160K0F
GP2D07J0000F
GP2D071J000F*
3
GP2Y2E301K0F
–10 to +60
5 ±0.5
TYP. 60
MIN. ±7.5
0.7 or less*
1
0 to +60
0 to +60
5 ±0.5
5 ±0.5
TYP. 60
TYP. 85
TYP. 36
TYP. 33
MAX. ±6
MAX. ±6
0.7 or less*
1
0.7 or less*
1
TYP. 33
GP2Y2A180K0F
–10 to +60
5 ±0.5
TYP. 80
MAX. 25
GP2Y2A280K0F
*1
*2
*3
*4
–10 to +60
5 ±0.5
TYP. 80
MAX. 50
GP2D03J0000F
(GP2D032J000F)
GP2D06J0000F
(GP2D061J000F/GP2D062J000F)
GP2Y2E101K0F
GP2Y2D160K0F
GP2Y2A180K0F
GP2D07J0000F
(GP2D071J000F)
GP2Y2E301K0F
GP2Y2A280K0F
Notice
In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that may occur in
equipment using any SHARP devices shown in catalogs, data books, etc.
Except where specially indicated, models listed on this page comply with the RoHS Directive*. For details, please contact SHARP.
*RoHS Directive: Prohibits use of lead, cadmium, hexavalent chromium, mercury and specific brominated flame retardants
(PBBs and PBDEs), with certain exceptions.
Contact SHARP in order to obtain the latest device specification sheets before using any SHARP device.
105
Optoelectronics
This table shows the characteristics when configured in the paper size sensor system.
Reflectivity: 18% or more, OD = log (1/T), T: Reflectivity
Paper detection height GP2D061: TYP. 45 mm GP2D062: TYP. 90 mm
Paper detection height GP2D071: TYP. 45 mm
Paper detection height GP2D032: TYP. 45 mm
Home Index Bookmark Pages Text