OPTICAL SYSTEM DEVICE
✩New
product
Distance Measuring Sensors (1)
Absolute maximum ratings
Model No.
Features
Vcc
(V)
(Ta = 25°C)
GP2D12J0000F
Distance measuring sensor united with PSD
,
infrared LED and signal processing circuit,
Linear voltage output
Distance measuring sensor united with PSD
,
infrared LED and signal processing circuit,
Linear voltage output
Distance measuring sensor united with PSD
,
infrared LED and signal processing circuit,
Linear voltage output
Light detector,
infrared LED and signal processing circuit,
short distance measuring sensor unit,
battery drive compatible
(operating power supply: 2.7 to 6.2 V)
Light detector,
infrared LED and signal processing circuit,
short distance measuring sensor unit,
battery drive compatible
(operating power supply: 2.7 to 6.2 V)
Light detector,
infrared LED and signal processing circuit,
short distance measuring sensor unit,
battery drive compatible (operating power supply:
2.7 to 6.2 V), Capable of operation at high
temperature
Digital voltage output according to the measured
distance of GP2Y0D340K
Compact, thin type (15 x 9.6 x 8.7 mm: sensor
part), Light detector, infrared LED and signal pro-
cessing circuit,Digital voltage output according to
the measured distance
Distance measuring sensor united with PSD
,
infrared LED and signal processing circuit,
Digital voltage output
Distance measuring sensor united with PSD
,
infrared LED and signal processing circuit,
Digital voltage output
Distance measuring sensor united with PSD
,
infrared LED and signal processing circuit,
Short measuring cycle (16.5 ms)
–0.3 to +7
GP2Y0A21YK0F
–0.3 to +7
GP2D120XJ00F
–0.3 to +7
Electro-optical characteristics*
1
Distance
Dissipation current Mea-
V
OL
V
OH
Topr
measuring
sured
(V)
(V)
Operating Standby distance
(°C)
range
MIN.
MAX.
(mA)
(µA)
(cm)
(cm)
V
O
(TYP.) = 0.4 V
(at L = 80 cm),
–10 to +60 10 to 80
MAX. 50
∆V
O
(TYP.) = 2.0 V
(at L: 80 cm
10 cm)
V
O
(TYP.) = 0.4 V
(at L = 80 cm),
–10 to +60 10 to 80
MAX. 40
∆V
O
(TYP.) = 1.9 V
(at L: 80 cm
10 cm)
V
O
(TYP.) = 0.4 V
(at L = 30 cm),
–10 to +60
4 to 30
MAX. 50
∆V
O
(TYP.) = 2.25 V
(at L = 30 cm
4 cm)
Vcc –0.6
0.6
MAX. 6.5 MAX. 8
5
GP2Y0D805Z0F
–0.3 to +7
–10 to +60
GP2Y0D810Z0F
–0.3 to +7
–10 to +60
Vcc –0.6
0.6
MAX. 6.5 MAX. 8
10
GP2Y5D91S00F
–0.3 to +7
–30 to +105
Vcc –0.6
0.6
TYP. 7
1.5
GP2Y0D310K
–0.3 to +7
–10 to +60
Vcc –0.3
0.6
MAX. 35
10
GP2Y0D340K
–0.3 to +7
–10 to +60
Vcc –0.3
0.6
MAX. 35
40
GP2D15J0000F
–0.3 to +7
–10 to +60
10 to 80
Vcc –0.3
0.6
MAX. 50
24
GP2Y0D21YK0F
–0.3 to +7
–10 to +60
10 to 80
Vcc –0.3
0.6
MAX. 40
24
GP2Y0A41SK0F
–0.3 to +7
–10 to +60
4 to 30
V
O
(TYP.) = 0.4 V
(at L = 30 cm),
∆V
O
(TYP.) = 2.25 V
(at L = 30 cm
4 cm)
Vcc –0.3
0.6
MAX. 22
Distance measuring sensor united with PSD
,
infrared LED and signal processing circuit,
GP2D150AJ00F
Digital voltage output
Distance measuring sensor united with PSD
,
GP2D150MJ00F▲ infrared LED and signal processing circuit,
Digital voltage output
Distance measuring sensor united with PSD
,
GP2Y0D413K0F
infrared LED and signal processing circuit,
Digital voltage output
Distance measuring sensor united with PSD
,
infrared LED and signal processing circuit,
GP2Y0D02YK0F
long distance measuring sensor unit
(No external control signal required), Digital volt-
age output according to the measured distance
–0.3 to +7
–10 to +60
3 to 30
MAX. 50
–0.3 to +7
–10 to +60
3 to 30
Vcc –0.3
0.6
MAX. 50
17.5
–0.3 to +7
–10 to +60
3 to 30
Vcc –0.3
0.6
13
–0.3 to +7
–10 to +60
20 to 150
Vcc –0.3
0.6
MAX. 50
80
*1 Vcc = 5 V
The model marked with
may not be available in the near future. Contact with SHARP for details before use.
PSD: Position Sensitive Detector
Notice
In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that may occur in
equipment using any SHARP devices shown in catalogs, data books, etc.
Except where specially indicated, models listed on this page comply with the RoHS Directive*. For details, please contact SHARP.
*RoHS Directive: Prohibits use of lead, cadmium, hexavalent chromium, mercury and specific brominated flame retardants
(PBBs and PBDEs), with certain exceptions.
Contact SHARP in order to obtain the latest device specification sheets before using any SHARP device.
103