OPTO
Phototriac Couplers
Internal
connection
diagram
Approved by
safety standards*
4
Type
Model No.
Features
UL
PHOTOTRIAC COUPLERS
:
Approved,
o:
Under application
(Ta = 25°C)
Absolute maximum ratings
Repetitive
Isolation
ON-state
peak
Package
voltage
current
OFF-state
I
FT
(AC)
Others
I
T
(rms)
voltage
(mA)
VDE
5
Viso (rms)
*
V
DRM
(A)
MAX.
(kV)
(V)
*
6
*
6
*
6
*
2
*
2
*
6
*
6
*
6
*
6
*
6
6-pin
DIP*
1, 3
800
600
400
4-pin
DIP
0.1
600
5.0
Mini-flat
4-pin
0.05
600
3.75
10
10
10
10
10
10
10
10
10
7
7
5
0.1
600
5.0
3
800
*
2
600
*
2
*
2
800
*
2
7
5
10
7
10
Electro-optical
characteristics
Min. trigger current
V
D
(V)
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
R
L
(Ω)
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
S2S3000F
S2S5A00F
PC3SG11YIZ0F▲
PC3ST11NSZAF
PC3SH11YFZAF
PC3SH13YFZAF
PC2SD11NTZAF*
7
For triggering
PC3SD12NTZAF*
8
PC3SD11NTZAF
PC3SD11NTZBF
PC4SD11NTZBF
PC3SD11NTZCF
PC3SD11YTZDF
PC4SD11NTZCF
PC3SF11YVZAF
PC3SF11YVZBF
PC4SF11YVZAF
PC4SF11YVZBF
200 V lines, compact
200 V lines, compact
200 V lines,
reinforced insulation
(isolation thickness: 0.4 mm)
200 V lines, compact
200 V lines, compact,
reinforced isolation
200 V lines, compact,
reinforced isolation,
High noise resistance
100 V lines
200 V lines
200 V lines
200 V lines
200 V lines,
repetitive peak-OFF-state voltage
200 V lines
200 V lines, low input drive
200 V lines,
repetitive peak-OFF-state voltage
200 V lines, reinforced isolation
200 V lines, reinforced isolation
200 V lines, reinforced isolation,
repetitive peak-OFF-state voltage
200 V lines, reinforced isolation,
repetitive peak-OFF-state voltage
*
6
For the note *1 to *9, see next page.
The model marked with
may not be available in the near future. Contact with SHARP for details before use.
76
Notice
In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that may occur in
equipment using any SHARP devices shown in catalogs, data books, etc.
Except where specially indicated, models listed on this page comply with the RoHS Directive*. For details, please contact SHARP.
*RoHS Directive: Prohibits use of lead, cadmium, hexavalent chromium, mercury and specific brominated flame retardants
(PBBs and PBDEs), with certain exceptions.
Contact SHARP in order to obtain the latest device specification sheets before using any SHARP device.
Home Index Bookmark Pages Text