HAT1008F
Power vs. Temperature Derating
2.0
Pch (W)
Test Condition :
When using the glass epoxy board
(40 x 40 x 1.6 mm)
1.5
–100
I
D
(A)
–30
–10
–3
–1
Maximum Safe Operation Area
10 µs 100 µs
PW
DC
1
Channel Dissipation
Drain Current
=
m
1.0
10
s
0.5
Operation in
–0.3 this area is
limited by R
DS(on)
–0.1
Ta = 25 °C
1 shot pulse
Op
er
at
io
m
s
n
**
–0.03
0
50
100
150
Ta (°C)
200
Ambient Temperature
–0.01
–1
–3
–10 –30 –100
–0.1 –0.3
Drain to Source Voltage V
DS
(V)
** When using the glass epoxy board
(40 x 40 x 1.6 mm)
Drain Current
Drain Current
Typical Output Characteristics
–10 V –8 V
–10
–6 V
V
–3.5
–5 V
–8
Pulse Test
–4.5 V
–4 V
–6
–3 V
–4
Typical Transfer Characteristics
–10
I
D
(A)
(A)
–8
Tc = –25 °C
25 °C
75 °C
I
D
–6
–4
–2
–2.5 V
V
GS
= –2 V
–2
V
DS
= –10 V
Pulse Test
0
–1
–2
–3
Gate to Source Voltage
–4
–5
V
GS
(V)
0
–2
–4
–6
Drain to Source Voltage
–10
V
DS
(V)
–8
3
Home Index Bookmark Pages Text
Previous Next